b urndy ehv h-10 welded terminal connector swa-a-n for cable w eld type application: cable to two or four hole pad (offset terminal) ehv rated: up to 550 kv when used with shielding caps material: cast 356 aluminum alloy catalog accommodates ? dia. max. max. fig. numbers alum. cable acsr cable str. dia. dia. no. b c d g h l n t 700 kcmil thru 605 kcmil thru 26-7 .961 1.085 1.50 4.00 4.25 1.12 2.00 6.25 1.12 .50 swa44r-44n 874.5 kcmil 874.5 kcmil 30-19 [24] [28] 1 [38] [102] [108] [28] [51] [159] [28] [13] 2000 kcmil thru 1.606 1.740 2.62 4.00 4.25 1.83 3.18 7.50 1.12 .82 swa48a-44n 2250 kcmil 2167 kcmil 72-7 [41] [44] 1 [67] [102] [108] [47] [81] [191] [28] [21] 1400 kcmil thru 1272 kcmil thru 1.341 1.470 2.00 4.00 4.25 1.38 2.56 6.56 1.12 .56 swa54r-44n 1600 kcmil 1510.5 kcmil 45-7 [34] [37] 1 [51] [102] [108] [35] [65] [167] [28] [14] 1700 kcmil thru 1510.5 kcmil thru 54-49 1.471 1.605 2.50 4.00 4.25 1.58 2.83 7.25 1.12 .69 swa58r-44n 1900 kcmil 1780 kcmil 54-19 [37] [41] 1 [64] [102] [108] [40] [72] [184] [28] [18] 900 kcmil thru 795 kcmil thru 1.086 1.210 1.75 4.00 4.25 1.21 2.19 6.56 1.12 .50 swa444a-44n 1100 kcmil 954 kcmil 54-7 [28] [31] 1 [44] [102] [108] [31] [56] [167] [28] [13] 1113 kcmil thru 1033.5 kcmil thru 45-7 1.211 1.340 2.00 3.00 3.00 1.22 2.31 5.44 .62 .50 swa454a-4n 1351.1 kcmil 1192.5 kcmil 54-19 [31] [34] 1 [51] [76] [76] [31] [59] [138] [57] [13] 2300 kcmil thru 2156 kcmil thru 84-19 1.741 1.875 2.62 3.00 3.00 1.84 3.31 6.12 .62 1.12 swa486a-4n 2500 kcmil 2300 kcmil 96-19 [44] [48] 1 [67] [76] [76] [47] [84] [156] [57] [28] 2300 kcmil thru 2156 kcmil thru 84-19 1.741 1.875 2.62 4.00 4.25 1.84 3.31 7.50 1.12 1.12 swa486a-44n 2500 kcmil 2300 kcmil 96-19 [44] [48] 1 [67] [102] [108] [47] [84] [191] [28] [28] 2300 kcmil thru 2156 kcmil thru 84-19 1.741 1.875 2.62 6.00 4.25 1.84 3.31 7.50 1.12 1.12 swa486a-66n 2500 kcmil 2300 kcmil 96-19 [44] [48] 2 [67] [152] [108] [47] [84] [191] [28] [28] 127 1.876 2.05 3.00 3.00 3.00 2.12 3.75 6.75 .62 1.00 swa493r-4n 3000 kcmil 169 [48] [52] 1 [76] [76] [76] [54] [92] [172] [16] [25] notes: 1. dimensions in brackets [ ] are in millimeters. 2. does not include shielding caps. for ehv applications, shielding caps are required. order separately (type) shown on page 32 or add suffix ?ts to catalog n umber (example: swa54r-44nsts), includes one shielding cap. 3. one surface of pad finished. for finished pad on both sides add suffix ? to the catalog number (example: swa22a-44nq). 4. for 45 or 90 degree angle add suffix ?5 or ?0 to catalog number (example: swa54r-44n90).
|